نوع مقاله : مقاله پژوهشی
عنوان مقاله English
نویسنده English
In the present study, a flat plate solar collector designed and manufactured by the author was tested and experimentally investigated. In the above collector, the arrangement of tubes in the two-sided absorber plate included riser tubes in front and spiral tubes in the back. The test was conducted under ASHRAE standard conditions and in Behbahan city in the southern Iran. The results of the study showed that although the riser piping, which is more exposed to bending in the front, has a higher efficiency, the use of piping behind the absorber can increase the efficiency of the collector set by more than 20%. The study included a thermal study of both types of piping and the performance of the collector was investigated based on the calculation of the collector efficiency under different parameters. For the test, the laboratory setup was first set up and each device was placed in the desired location as shown in Figure 1. Accordingly, the working fluid is transferred from the tank to the pump and then to the collector inlet. The working fluid at the collector inlet reaches three ways, which are the ability to pass through the pipe arrangement with riser (in front of the absorber) or through the spiral pipe arrangement (behind the absorber) or all the valves are open and allowed to pass through both sides. Then the fluid is discharged from the collector and re-enters the tank. The fluid flow rate is also measured at the beginning of each experiment. During the experiment, environmental data such as humidity, wind speed, air temperature and solar radiation were measured along with the outlet and inlet temperatures. Investigation of the collector with a double-sided absorber shows that its efficiency increases with increasing radiation and the trend of efficiency changes based on increasing wind speed and air humidity is increasing and decreasing, respectively. Also, for further investigation, water-silver nanofluid was used in three concentrations of 1000, 1500 and 2000 ppm and it was found that the use of nanofluid increased the collector efficiency, which is due to Brownian motion and different flows in the pipes. The maximum efficiency achieved at the highest nanofluid concentration reached about 64.1%, which was more than 13% higher than the average of pure water. During the experiment, environmental factors and parameters were also measured and analyzed, and the maximum uncertainty was reported to be 3.08.
کلیدواژهها English