Hybrid solid oxide fuel cell–gas turbine (SOFC–GT) cycles couple electrochemical conversion with thermal energy recovery. Changes in operating conditions therefore affect electrical performance and stack temperature simultaneously, making the evaluation of operating points under thermal constraints important. This study develops a physics-embedded neural surrogate for the pressurized 220 kW Siemens–Westinghouse SOFC–GT cycle. The framework combines a steady-state thermodynamic reference model, an ensemble of neural networks, explicit physical relations, and conservative thermal screening to support operating-point assessment while retaining the reference model for cases requiring direct evaluation.
A zero-dimensional, steady-state model was developed using Engineering Equation Solver (EES). At the design point, the model reproduced 222.04 kW of net electrical power and a net electrical efficiency of 51.47%. Predictions from several neural networks were combined, while the dependent quantities of net power, electrical efficiency, and current density were reconstructed using explicit physical relations. This structure maintains consistency among the reconstructed quantities rather than treating all outputs as independent neural predictions.
The neural surrogate was evaluated against 256 new EES simulation scenarios. The root mean square error (RMSE) was 0.483 kW for net power and 0.761 °C for maximum stack temperature. A conservative temperature margin of 2.333 °C was then applied to the operating-point screening procedure. Of the 256 scenarios, 124 were conditionally accepted and 132 were referred for direct EES evaluation. According to the EES calculations, 64 scenarios exceeded the maximum allowable stack temperature, and none of these scenarios was incorrectly accepted by the screening procedure.
Scenario-based multi-objective optimization over nine thermal scenarios identified 72 non-dominated operating points representing alternative power–efficiency compromises. An additional 108 EES evaluations of selected candidate points satisfied the specified numerical and physical feasibility criteria. Taken together, the results demonstrate that neural predictions combined with explicit physical relations can provide rapid, physically consistent performance estimates and conservative thermal screening for selecting operating points in the investigated hybrid system. The reported evaluation is numerical and based on the EES reference model.
کلیدواژهها English